Renewable Energy for Developers

Video walkthrough · YouTubeRenewable Energy for Developers: kW vs kWh, Solar, Wind, Batteries & Dashboards That Add Up

Power is a rate (kW) and energy is an amount (kWh); most renewable dashboard bugs confuse the two. A wind or solar plant cannot choose its output — the weather does — so analytics is always actual versus expected: what the plant delivered compared with what it could have delivered given the sun or wind it saw. The grid must match supply and demand every second, and storage, forecasting, and markets all exist to cope with supply nobody can dispatch.

TermMeaning
kW, MWPower — an instantaneous rate
kWh, MWhEnergy — power × time
MWpPV DC peak power at test conditions
MWacInverter or grid-export limit
CapacityNameplate maximum, not output

Energy for an interval is average power times the interval length in hours: 1 MW held for 15 minutes is 0.25 MWh. A “100 MW plant” tells you the ceiling, not how much it produced. Solar plants quote both DC (MWp) and AC (MWac) capacity, so every label on a chart must say which.

// Average kW per 15-min interval → kWh
const kw = [400, 420, 410, 390];
const hours = 15 / 60;
const kwh = kw.reduce(
(sum, p) => sum + p * hours,
0,
);
console.log(kwh); // 405

Gotcha: summing raw power samples is not energy. Sixty 1-minute kW readings summed are sixty times the kWh — multiply each by its interval in hours, or average power and multiply once.

TermMeaning
GHIGlobal horizontal irradiance, W/m²
POAPlane-of-array irradiance on the module
STC1000 W/m², 25 °C cell, AM1.5 spectrum
DC/AC ratioMWp ÷ MWac, usually above 1
ClippingInverter caps output at its AC rating
SoilingDirt on modules blocking light

PV output tracks POA irradiance closely and drops as cells heat up. Designers oversize the DC array so inverters run near full rating for more hours, accepting some midday clipping. Modules also degrade slowly — a median around 0.5 % per year in field studies — so year-on- year comparisons must allow for it.

const kwp = 1200; // DC nameplate
const kwAc = 1000; // inverter limit
const poa = 900; // W/m² measured
const loss = 0.85; // temp, soiling, wiring
const dc = kwp * (poa / 1000) * loss;
const ac = Math.min(dc, kwAc);
console.log(Math.round(ac)); // 918

Gotcha: a flat top on a sunny-day power curve is clipping, not a stuck sensor or an outage. Alerting on it pages someone for a design decision.

TermMeaning
Cut-in speedWind speed where output starts
Rated speedWind speed reaching nameplate power
Cut-out speedShutdown to protect the turbine
Power curveExpected power per wind-speed bin
Hub heightHeight the wind is measured for

Power in the wind is ½ρAv³: it grows with the cube of wind speed, so doubling the wind gives eight times the power, until the turbine hits rated output. No rotor can extract more than 16/27 (about 59 %) of it — the Betz limit. Official power curves bin 10-minute averages into 0.5 m/s wind-speed bins.

const rho = 1.225; // air density, kg/m³
const area = Math.PI * 60 ** 2; // 120 m rotor
const watts = (v: number) =>
0.5 * rho * area * v ** 3;
console.log(watts(10) / watts(5)); // 8

Gotcha: never feed a power curve a daily or monthly average wind speed. Because of the cube, the mean of v³ is larger than the cube of mean v, so averaging first underestimates energy.

TermMeaning
MW / MWhPower rating / energy capacity
DurationMWh ÷ MW — 400 MWh / 100 MW = 4 h
SoCState of charge, % of usable energy
SoHCapacity remaining versus new
C-rateMW ÷ MWh; 1C empties in one hour
RTERound-trip efficiency, energy out ÷ in

A battery energy storage system (BESS) earns money by arbitrage — charging when power is cheap, discharging when it is dear — and by grid services such as frequency response. NREL’s planning baseline assumes 85 % round-trip efficiency for utility-scale lithium-ion. Cycle count and depth of discharge drive degradation, which shows up as falling SoH.

const mw = 100;
const mwh = 400;
const durationH = mwh / mw; // 4
const cRate = mw / mwh; // 0.25
const chargedMwh = 200;
const outMwh = chargedMwh * 0.85; // 170

Gotcha: vendors disagree on sign: some report charging as positive power, others as negative. Normalize the sign at ingestion and document it, or a battery appears to create energy.

KPIFormula
Capacity factorEnergy ÷ (nameplate × hours)
Specific yieldkWh ÷ kWp, in hours
Performance ratioFinal yield ÷ reference yield
AvailabilityAvailable ÷ possible (time or energy)
CurtailmentPossible energy − delivered energy

Capacity factor is mostly weather and site: the US fleet runs around 23 % for utility solar and 34 % for wind. Performance ratio (IEC 61724-1) divides out irradiance, so it measures losses rather than weather — the right metric to compare plants. Availability (IEC 61400-26-1) is either time-based or production-based; a turbine down on a calm day loses hours but little energy.

const kwp = 1000; // DC nameplate
const kwh = 4200; // AC energy, one day
const poa = 5.2; // kWh/m², one day
const yf = kwh / kwp; // final yield, h
const yr = poa / 1; // ref yield, h (1 kW/m²)
const pr = yf / yr; // ≈ 0.81
const cf = kwh / (kwp * 24); // 0.175

Gotcha: always state the denominator. A capacity factor on MWp and one on MWac differ by the DC/AC ratio, and both get called “capacity factor” in the same meeting.

TermMeaning
PPALong-term contract buying plant output
LCOEDiscounted lifetime cost ÷ energy
Day-ahead / real-timeMarket cleared ahead vs near delivery
ImbalancePenalty for missing your forecast
REC / GOCertificate per MWh green (US / EU)
Frequency50 Hz Europe, 60 Hz North America

Grid frequency drifts whenever supply and demand differ, so operators pay for reserves and frequency response. Wind and solar have near-zero marginal cost, bid low in the merit order, and push prices down — at times below zero. Plants bid on forecasts, so forecast error has a direct imbalance cost. Emissions are energy times a grid emission factor in gCO₂/kWh.

const mwh = [40, 55, 60];
const price = [52, 8, -15]; // EUR/MWh
const revenue = mwh.reduce(
(sum, e, i) => sum + e * (price[i] ?? 0),
0,
);
console.log(revenue); // 1620

Gotcha: at negative prices, generating loses money, so curtailing is the correct call. A dashboard that counts every curtailed MWh as lost revenue punishes the operator for doing the right thing.

TermRole
SCADAPlant control and data acquisition
Modbus TCP / RTUPolling of numbered 16-bit registers
OPC UATyped, browsable industrial data model
IEC 61850Substation and DER communication
PPCPower plant controller, sets site output
Met stationIrradiance, wind, temperature sensors

Inverters, turbines, meters, and sensors talk to an on-site gateway, which forwards to the cloud over MQTT or HTTPS. Web developers rarely touch devices directly, but every value arrives with a tag name, unit, and often a scale factor. Modbus registers are 16-bit and big-endian; a 32-bit value spans two registers.

// Two 16-bit registers → one float32
const [hi, lo] = [0x4479, 0xc000];
const view = new DataView(new ArrayBuffer(4));
view.setUint16(0, hi); // high word first
view.setUint16(2, lo);
console.log(view.getFloat32(0)); // 999

Warning: Modbus does not define the word order of 32-bit values, and vendors differ. Swapped words give plausible-looking wrong numbers, not an error — check one value against the device display.

PitfallFix
Interval labelsStore interval start and length
DST 23- and 25-hour daysStore UTC, convert for display
Summing powerAverage power; sum energy
Cumulative meter countersDifference reads, handle resets
Gaps and frozen valuesQuality flag; never fill silently

Revenue meters keep a running kWh register; differencing consecutive reads gives billing-grade interval energy, better than integrating power. Store telemetry as a narrow table — asset, signal, UTC timestamp, value, quality — and pre-aggregate raw → 15 min → day for dashboards.

CREATE TABLE meter (ts TEXT, kwh_total REAL);
INSERT INTO meter VALUES
('2026-06-01T10:00Z', 1000.0),
('2026-06-01T10:15Z', 1105.5),
('2026-06-01T10:30Z', 1210.0);
-- interval energy from a running counter
SELECT ts,
kwh_total - LAG(kwh_total)
OVER (ORDER BY ts) AS kwh
FROM meter;
-- 10:15 → 105.5, 10:30 → 104.5

Gotcha: US power markets label hours as hour-ending: “HE 14” is 13:00–14:00. Joining hour-ending prices to period-beginning generation shifts every row by an hour, and the result still looks plausible.

QuestionShort answer
kW vs kWh?Rate vs amount; kWh = avg kW × h
Why is solar CF ~25 %?Night and weather, not inefficiency
P50 vs P90?Yield exceeded with 50 % / 90 % odds
Why DC/AC above 1?More full-power hours; some clipping
PR vs CF?PR removes weather; CF does not
Detect underperformance?Actual vs modelled expected output

Expect a system-design prompt as well. A strong answer for “dashboard for 200 solar sites” covers:

  • Ingest: gateway → MQTT → stream → time-series store
  • Model: narrow table, UTC, units and quality per signal
  • Roll-ups: precomputed 15-min, daily, monthly aggregates
  • Alerts: PR or availability below fleet peers, not below yesterday
  • Lost energy: expected minus actual, split by cause

Tip: lenders size debt on P90 — the yield exceeded in nine years out of ten — so finance users want P50 and P90 lines on every long-term production chart.